OpenVentilator
Bem vindo a pagina oficial do OpenVentilator!
Our main Goal
Design, build and test a reliable mechanical ventilation medical equipment to help the COVID-19 people / regions / countries in deep humanitarian crisis or difficult economic situations. (That is why we do not continue our efforts on projects that are being developed by other teams, which have a different society and economic approach), we discard ambu / stepper motors / complex valves / central compressed air).Cities are running out of Ambubags, so we developed a bellows system that can be built with 4 discs, a wheel chamber. We used a 12V DC wiper motor, a set of relays, keys and diodes found in cars in addition to a computer source
As cidades estão ficando sem Ambubags, então desenvolvemos um sistema de fole que pode ser construído com 4 discos, câmara de roda. Usamos um motor de limpa-parabrisa 12V DC um jogo de reles, chaves e diodos encontrados em carros alem de uma fonte de computador
Documentation & Repo
Conheça as especificações do nosso projeto, siga as regras e o Código de Conduta. Compartilhe idéias no Slack, abra apenas problemas no GitHub depois de identificar problemas críticos da missão
We are developing a solution that can be easily implemented horizontally without the need for large industries, as an industrial park is not the reality in many cities in Brazil. In addition, we are approaching the project in a completely different way.
Nos últimos tempos, vimos todos os tipos de projetos de respiradores. Mas nenhum destinado aos países do terceiro mundo. A verdade é que nem mesmo os países do primeiro mundo estão conseguindo acompanhar a demanda.
Nosso respirador, apesar de muito humilde, segue os requisitos clínicos necessários para atender pacientes com Covid-19.
Another important point is the change in the approach to the use of "Ambu". These pulmonary resuscitators, although easily found in large cities, are not found in small villages and poor countries, it is also questionable whether they could withstand the ventilation of a patient for 20 intubated days. Therefore, our project replaces Ambu with a bellows, exactly the same as the way old hospital respirators used to do


Requisitos finais do respirador Espartano
-
VCV Volume Control Ventilation
-
Max Overpressure Valve Control (mechanical)
-
Peep Pressure mechanical adjustment
-
Easy to build bellow system
-
Inspiratory control
-
Expiratory control
-
Automatic diverter flow valve
-
Filtering of expiatory air by radiation and chemical process
-
Easy to build and off-the-shelf parts
-
Without fancy electronics
-
Bad ass and reliable engineering
#OPENVENTILATOR